PERANCANGAN DAN REALISASI FUNCTION GENERATOR FREKUENSI MAKSIMAL 2MHZ

Moh. Vita Nur Adhitya

Informasi Dasar

611100007
621.381
Karya Ilmiah - TA (D3) - Reference

ABSTRAKSI: Laboratorium Elektonika Komunikasi (Lab ELKOM) merupakan salah satu Laboratorium di IT Telkom. Laboratorium ini telah berhasil merancang satu set kit praktikum yang terdiri dari kit Osilator, kit Mixer, kit Filter, kit Penguat Daya dan kit Phase Lock Loop. Namun, ada beberapa kendala pada proyek tersebut diantaranya adalah dibutuhkannya alat pendukung yaitu Function Generator 2 Mhz dan dipasaran belum ada institusi yang menjual Function Generator 2 Mhz yang bisa dibawa dengan beban lebih ringan dan dengan harga yang masih terjangkau. Oleh karena itu, pada Proyek Akhir ini ingin membuat “Perancangan dan Realisasi Function Generator Frekuensi Maksimal 2 MHz”.

Alat yang akan dirancang terdiri atas input-output, catu daya, blok Function Generator, blok pengubah sinyal sinusoidal, blok output. Prinsip kerja dari alat ini adalah ketika alat tersebut diberi catuan dari catu daya maka arus tersebut akan diolah oleh osilator IC NE-566. IC NE-566 ini dapat menghasilkan sinyal maksimal 1 Mhz. Oleh karena untuk kit praktikum dibutuhkan sinyal maksimal sebesar 2 MHz maka IC tersebut dibutuhkan pengali atau yang biasa di sebut (adjust) agar nilai frekuensinya menjadi maksimal 2 MHz sesuai dengan ketentuan kit. IC NE-566 dapat menghasilkan output sinyal berupa sinyal segitiga dan sinyal persegi. Untuk memperoleh sinyal sinusoidal dapat didapatkan dengan mengkonversi sinyal segitiga dengan bantuan blok pengubah sinyal sinusoidal. Dalam aplikasinya amplitudo dan frekuensi output siyal sinusoidal alat ini dapat diatur oleh potensiometer.

Hasil dari perancangan ini adalah sebuah function generator ini dapat menghasilkan sinyal keluaran dengan frekuensi maksimal 2Mhz. Output keluaran dibedakan menjadi tiga macam yaitu berbentuk fasa gelombang sinusoidal, gelombang persegi dan gelombang segitiga sesuai dengan spesifikasi yang ditentukan.keluaran. sinyal terbaik adalah sinusoidal tipe B karena dapat menghasilkan frekuensi sampai 2MHz dan dapat mempertahankan bentuk duti cycle fasa yang stabil ±50%. Alat ini hanya dapat diatur amplitudonya antara range 2 Volt – 4.8Volt. Dapat di simpulkan alat ini bisa digunakan untuk praktikum karena kompatibel dengan kit praktikum yang telah ada.Kata Kunci : Function Generator, sinusoidal, frekuensi, amplitudoABSTRACT: Elektonika Communication Laboratory is one of the laboratory in IT Telkom. This laboratory has successfully designed a set of lab kit that consists of a Oscillator kit, Mixer kit, filter kit, Power Amplifiers kit and Phase Lock Loop kit. However, there are some constraints on the project include the need for a tool to support the Function Generator 2 MHz and the market there is no institution that sells small 2 Mhz Function Generator can be taken with a lighter load and at a price that is still affordable. Therefore, the final project wants to make "Design and Realization of Function Generator 2 MHz Maximum Frequency"

Tool will be designed consists of input-out, power supply, function generator block, block sinusoidal signal converter, frequency control and Vpp. The working principle of this device when the device is given a portion of the current power supply will be processed by the oscillator IC NE-566. IC NE-566 can generate signals up to 1 MHz. Therefore for lab kit is required for maximum signal IC 2 MHz then the multiplier needed or commonly called the (adjusted) to a maximum value of 2 MHz frequency in accordance with the provisions of kit. IC NE-566 can produce the output signal in the form of signals and signal triangular square. To obtain a sinusoidal signal can be obtained by converting the triangular signal with the help of a sinusoidal signal converter block. In its application and frequency output amplitude sinusoidal signal this tool can be set by the potentiometer

This design is the result of a function generator can produce a maximum output signal with a frequency of 2MHz. Output output can be divided into three types namely-shaped phase sinusoidal wave, square wave and triangular wave in accordance with defined specifications. sinusoidal output signal type B is best because it can maintain duty form a stable cycle phase ± 50%. T This tool can only be set in amplitude between 2.5 Volt range – 4.8Volt and it supports the tool so that it can be used for practical as it is compatible with existing lab kit.Keyword: Function Generator, sinusoidal, frequency, amplitude

Subjek

Sistem Elektronika
 

Katalog

PERANCANGAN DAN REALISASI FUNCTION GENERATOR FREKUENSI MAKSIMAL 2MHZ
 
 
Indonesia

Sirkulasi

Rp. 0
Rp. 0
Tidak

Pengarang

Moh. Vita Nur Adhitya
Perorangan
Mas Sarwoko Suraatmadja, Unang Sunarya
 

Penerbit

Universitas Telkom
Bandung
2013

Koleksi

Kompetensi

 

Download / Flippingbook

 

Ulasan

Belum ada ulasan yang diberikan
anda harus sign-in untuk memberikan ulasan ke katalog ini